Unsatisfactory EICR: What Landlords Must Do Next

You’ve arranged an Electrical Installation Condition Report (EICR) for your rental property, only to receive a report marked Unsatisfactory.

Electrician inspecting a consumer unit following an unsatisfactory EICR

Naturally, you have questions. Is the property unsafe? How much work is required? Will you need a new consumer unit or even a complete rewire? And how quickly must everything be resolved.

The good news is that an unsatisfactory EICR does not automatically mean extensive or expensive electrical work.

What matters is understanding the findings, identifying which issues require action and ensuring the appropriate remedial work is completed and documented.

Here’s what landlords in England need to know.

What Does an Unsatisfactory EICR Mean?

An EICR assesses the condition of a property’s fixed electrical installation, including its wiring, consumer unit, circuits and associated electrical accessories. The inspection identifies defects, potential safety concerns and areas where improvements may be recommended.

An unsatisfactory result means that the inspection has identified at least one issue requiring remedial work or further investigation before the installation can be considered satisfactory. However, not every observation represents the same level of risk.

Understanding the classification codes is the first step towards deciding what happens next.

EICR Codes Explained: C1, C2, C3 and FI

C1: Danger Present

A C1 observation identifies an immediate danger, with a risk of injury. Examples could include exposed live electrical parts that are accessible and present a danger of electric shock. Immediate action is required. The inspecting electrician may need to make the affected part of the installation safe before leaving the property.

C2: Potentially Dangerous

A C2 observation identifies a defect that could become dangerous under certain conditions. Examples may include inadequate electrical protection or defects that create a potential risk of electric shock or fire. Urgent remedial action is required. The exact work will depend on the defect identified and the condition of the installation.

FI: Further Investigation Required

FI identifies a concern that may need further investigation or testing. Its effect on the overall EICR assessment depends on the edition of BS 7671 used. The investigation should establish the cause and appropriate action.

C3: Improvement Recommended

A C3 observation identifies an improvement that would be beneficial but is not, by itself, grounds for an unsatisfactory EICR. For example, an older installation may have features that do not reflect current installation practices but do not necessarily present a defect requiring mandatory remedial action. Landlords can consider these recommendations as part of planned electrical improvements. A C3 recommendation should not automatically be presented as compulsory remedial work.

How Long Does a Landlord Have to Complete EICR Remedial Works?

Under the electrical safety regulations applying to privately rented properties in England, landlords must arrange required investigative or remedial work within 28 days of the inspection and testing, or within a shorter period specified in the report. This does not mean landlords should wait 28 days before responding to a serious safety concern.

C1 observations require immediate attention and C2 observations require urgent remedial action. FI findings should be considered in the context of the edition of BS 7671 used and any other identified safety concerns. The 28-day period is generally the maximum statutory timeframe, not a recommended waiting period.

Landlords must also obtain written confirmation from a qualified person following the required work or investigation, and provide the required documentation to tenants and, where applicable, the local authority within the relevant timescales. For managing agents, this makes prompt communication and clear arrangements particularly important.

Does an Unsatisfactory EICR Mean the Property Needs Rewiring?

Electrician working on electrical wiring during inspection or repair

No. An unsatisfactory EICR does not automatically mean a complete rewire is required.

This is one of the most common concerns landlords have when receiving an unsatisfactory electrical report.

Some defects may be resolved through relatively localised repairs or improvements.

Depending on the findings, these might include:

  • Replacing damaged electrical accessories.
  • Repairing a defective circuit or connection.
  • Correcting inadequate protective arrangements.
  • Investigating an insulation resistance fault.
  • Addressing specific consumer unit or circuit defects.

Other installations may require more extensive work, particularly where deterioration or widespread defects are identified.

However, the appropriate recommendation should follow the evidence gathered during inspection and testing.

Does an Older Consumer Unit Need Replacing?

Not necessarily. An older consumer unit is not automatically unsafe simply because newer products and protective devices are available.

The electrician must consider the installation’s actual condition, protective arrangements and relevant safety requirements. A consumer unit replacement may be justified where defects or inadequate protection require it, but age alone should not be used as the sole reason for recommending an expensive upgrade.

The distinction between necessary remedial work and recommended improvement matters. Landlords should understand what they are being asked to approve and why.

What Happens After an Unsatisfactory EICR?

The next stage should be a clear, organised process.

1. Review the Electrical Report

Start by identifying the observations responsible for the unsatisfactory result. Pay particular attention to C1 and C2 classifications, and check how any FI observations are treated under the edition of BS 7671 used for the report. If anything is unclear, ask for an explanation of the defect and its implications.

2. Identify Immediate and Urgent Safety Issues

Any immediate danger must be addressed without delay. Where necessary, the affected electrical circuit or equipment may need to remain isolated until the issue has been made safe.

3. Obtain a Clear Remedial Quotation

The quotation should identify the work required to address the report’s findings. It should distinguish essential remedial work from optional improvements wherever possible. Further diagnostic investigation may be necessary before the full scope can be confirmed.

4. Arrange the Appropriate Electrical Work

Required works should be undertaken by a suitably qualified and competent person. The timescale must reflect the seriousness of the findings and the applicable legal requirements.

5. Obtain Written Confirmation

Once the work or investigation has been completed, the landlord must obtain appropriate written confirmation. Depending on the work, this may include an Electrical Installation Certificate, a Minor Electrical Installation Works Certificate, or other suitable confirmation from the qualified person. The documentation must adequately establish whether the required issues have been resolved and whether further action is necessary.

6. Keep the Complete Record

Retain the original EICR, details of the remedial work, relevant certification and written confirmation. Supply the required documents to the tenant and local authority where legally required. This creates a clear record of the original findings and how they were addressed.

Do You Need Another EICR After Remedial Work?

Not automatically. A full repeat EICR is not necessarily required every time remedial work is completed. The original report identifies the defects, while the subsequent documentation should confirm the work undertaken and the resulting electrical safety position.

The appropriate certification depends on the nature and extent of the work. In some circumstances, additional inspection or testing may be necessary to establish that the relevant issues have been resolved. Landlords should not assume that an invoice marked completed is sufficient evidence of compliance.

The important question is whether the documentation clearly confirms the outcome of the required remedial work and any investigation.

Why Electrical Compliance Records Matter

An EICR is only one part of the property’s electrical safety history. Consider what happens when an inspection identifies several defects, a contractor completes the repairs and the managing agent subsequently changes. Can the landlord still demonstrate which observations were addressed, when the work was completed and what certification was issued?

This is why maintaining accurate property records matters. The original inspection report, remedial quotation, completed work and supporting documentation should remain connected to the property. For landlords managing several properties, this becomes especially important.

Through MyMatrixHub®, CRS Matrix supports the organisation of property compliance information, helping landlords and agents maintain visibility of inspections, documentation and property history. Property History Matters.

How CRS Matrix Helps Leicester Landlords

At CRS Matrix, we support landlords and managing agents across Leicester and Leicestershire with electrical safety inspections, fault investigation and remedial work. Our approach is straightforward.

We help identify what the report means, distinguish necessary work from advisory improvements and arrange the appropriate next steps. Where remedial work is required, we can assist with quotations, coordinating suitably qualified electrical contractors and maintaining the resulting documentation.

Whether you manage one rental property or a larger portfolio, the objective remains the same: resolve the identified issues, establish the appropriate electrical safety position and keep clear records of what has been completed.

Frequently Asked Questions

Can I Rent Out a Property With an Unsatisfactory EICR?

An unsatisfactory EICR identifies electrical safety issues requiring action. Landlords must ensure the applicable safety standards are met and arrange required investigation or remedial work within the statutory timeframe, or sooner where necessary. An unsatisfactory report should not be treated as evidence that the property is safe for occupation.

Is a C2 Observation a Failed EICR?

Yes. A C2 observation means the installation is potentially dangerous and results in an unsatisfactory overall assessment.

Do C3 Observations Have to Be Fixed?

Not simply because they are recorded as C3. These are recommendations for improvement rather than mandatory remedial findings under the electrical safety reporting requirements. Other circumstances may independently justify work.

Can a Landlord Use a Different Electrician for Remedial Work?

Yes. The remedial work does not necessarily have to be undertaken by the electrician who carried out the original EICR. The person completing the work must be suitably qualified and competent.

Will I Need to Pay for Another Full Electrical Inspection?

Not necessarily. Appropriate certification and written confirmation following the remedial work may be sufficient. Additional inspection or testing may be required depending on the findings.

What If the Remedial Work Cannot Be Completed Within 28 Days?

Landlords should act promptly, document the steps taken and seek appropriate advice. The regulations make provision for situations where a landlord can demonstrate that all reasonable steps have been taken to comply. However, this should not be treated as an automatic extension or a reason to delay addressing safety concerns.